- Online only
-
idroenergiaitalia solenoid valves Ode acl
- Indirect or servo-controlled solenoid valves ODE - idroenergiaitalia
- solenoid valves direct control 2 or 3 ways ODE ACL - idroenergiaitalia
- mixed control solenoid valves minimum operating pressure 0 bar - idroenergiaitalia
- ode acl pneumatic control valves, camozzi pneumax pneumatic solenoid valves
-
solenoid valves for car wash autoequip aquarama istobal ceccato 48v 24v idroenergiaitalia
- solenoid valve wax floor cleaner degreaser alkaline liquid
- one-way non return check valves 316 stainless steel 250 bar peek core
- check valves non-return valve brass ITAP EUROPA
- ball valve in 316 stainless steel PTFE PN67
- brass ball valve water autoclave irrigation electropumps
- 21H7KV120, 21H8KV120, 4743K0V120, 21A2KV25, 21A2KV30, 4966K0Q120, 21WA4K0V130
- SOLENOID VALVE WITHOUT COIL SOLENOID MAGNET VALVE BODY ONLY
- 21H7KE120 21H8KE120 4743K0E120 21A2KE20 21A2KE25 21A2KE30 21A3KE20 21A3KE25 21A3KE30
- bistable solenoid valves latch impulse 6v 9v 12v 24v
- 12v solenoid valves for sprayers for plant protection weeding - idroenergiaitalia EVY69KV110
-
solenoid valves aviation fuel diesel diesel petrol agricultural 12v 24v 110v 220v idroenergiaitalia
- idroenergiaitalia-ode-21TG1KR0V17-21TG1KR0V22-21TG1KR0V28-21TG1KR0V40
- idroenergiaitalia-ode-21TG2KR0V17-21TG2KR0V22-21TG2KR0V28-21TG2KR0V40
- solenoid valve for car anti-theft 12v 24v lock Passage petrol Diesel fuel - idroenergiaitalia
- SOLENOID VALVE 3/4 N.C. FUEL DIESEL PETROL IDROENERGIAITALIA
- SOLENOID VALVE 1/2 N.C. FUEL DIESEL PETROL IDROENERGIAITALIA
- analog timer - idroenergiaitalia
- compatible solenoid valves for coffee machines marzocco new simonelli spm space
- solenoid valves cold water -10° + 90° - idroenergiaitalia
-
solenoid valves stainless steel aisi 316 gaskets in viton or teflon - idroenergiaitalia
- 21IH2K1V110, 21IH3K1V150, 21IH4K1V160, 21IH5K1V200, 21IH6K1V250, 21IH7K1V350, 21IH8K1V400,
- 21X2KV120, 21X3KV190, 21X4KV250, 21X2KT120, 21X3KT190, 21X4K1T250,
- 21JL1R1V12, 21JL1R1V23, 31JL1XP1V12, 31JL1XP1V12-S, 31JL1XP1V12-PB, 21L2K1V15-XC,
- 21L1K1T25, 21L1K1T30, 21L1K1T40, 21L2K1T25, 21L2K1T30, 21L2K1T40, 21L2K1T55,
- 21L1K1V25, 21L1K1V30, 21L1K1V40, 21L2K1V25, 21L2K1V30, 21L2K1V40, 21L2K1V55,
- 21L1K1E25, 21L1K1E30, 21L1K1E40, 21L2K1E25, 21L2K1E30, 21L2K1E40, 21L2K1E55,
- 31L1A1T30-R, 31L2A4T30, 31L2A1V30, 31L2F0V15-U, 21L1K1T15-XC,
- solenoid valves steam 180 ° overheated hot water
- pilot solenoid valves for pneumatic actuators - solenoid pilot - idroenergiaitalia
- solenoid valves dryers compressed air condensate drain
- weeding solenoid valves, atomizer, spraying, disinfestation - idroenergiaitalia
- solenoid valves for electrolux bosh whirpool aeg beko elbi bitron
- total separation solenoid valves for medical equipment - idroenergiaitalia
- solenoid valves equipment equipment assistance dental dentists
- degreased solenoid valves for industrial oxygen OX technical gases
- solenoid valve 12v dc direct current battery powered
- NSF certified ODE solenoid valves for food fluids
- solenoid valve for refrigerant gas R 134a, R 404a etc.
- high pressure solenoid valves compressed air co2 water fire
- compressed air solenoid valves normally closed and open - idroenergiaitalia
- hot water solenoid valve - heating solenoid valve - radiator solenoid valve - idroenergiaitalia
- acl solenoid valve compatible comac lavorwash tennants nilfisk fimap
- Indirect or servo-controlled solenoid valves ODE - idroenergiaitalia
- solenoid valves direct control 2 or 3 ways ODE ACL - idroenergiaitalia
- mixed control solenoid valves minimum operating pressure 0 bar - idroenergiaitalia
- ode acl pneumatic control valves, camozzi pneumax pneumatic solenoid valves
-
solenoid valves for car wash autoequip aquarama istobal ceccato 48v 24v idroenergiaitalia
- solenoid valve wax floor cleaner degreaser alkaline liquid
- one-way non return check valves 316 stainless steel 250 bar peek core
- check valves non-return valve brass ITAP EUROPA
- ball valve in 316 stainless steel PTFE PN67
- brass ball valve water autoclave irrigation electropumps
- 21H7KV120, 21H8KV120, 4743K0V120, 21A2KV25, 21A2KV30, 4966K0Q120, 21WA4K0V130
- SOLENOID VALVE WITHOUT COIL SOLENOID MAGNET VALVE BODY ONLY
- 21H7KE120 21H8KE120 4743K0E120 21A2KE20 21A2KE25 21A2KE30 21A3KE20 21A3KE25 21A3KE30
-
solenoid valves stainless steel aisi 316 gaskets in viton or teflon - idroenergiaitalia
- 21IH2K1V110, 21IH3K1V150, 21IH4K1V160, 21IH5K1V200, 21IH6K1V250, 21IH7K1V350, 21IH8K1V400,
- 21X2KV120, 21X3KV190, 21X4KV250, 21X2KT120, 21X3KT190, 21X4K1T250,
- 21JL1R1V12, 21JL1R1V23, 31JL1XP1V12, 31JL1XP1V12-S, 31JL1XP1V12-PB, 21L2K1V15-XC,
- 21L1K1T25, 21L1K1T30, 21L1K1T40, 21L2K1T25, 21L2K1T30, 21L2K1T40, 21L2K1T55,
- 21L1K1V25, 21L1K1V30, 21L1K1V40, 21L2K1V25, 21L2K1V30, 21L2K1V40, 21L2K1V55,
- 21L1K1E25, 21L1K1E30, 21L1K1E40, 21L2K1E25, 21L2K1E30, 21L2K1E40, 21L2K1E55,
- 31L1A1T30-R, 31L2A4T30, 31L2A1V30, 31L2F0V15-U, 21L1K1T15-XC,
- camozzi coils, camozzi solenoids, camozzi magnets, camozzi electromagnet,
-
spare parts pistons membranes movable cores sleeves coils solenoids connectors solenoid valves ode
-
Coils solenoids magnets electromagnets ode acl camozzi parker pneumax ceme - idroenergiaitalia
- BDA08012AS, BDA08012CS, BDA08024CS, BDA08024DS, BDA08110DS, BDA08223DS
- BDA08048AS, BDA08048CS, BDA08042AS,BDA08230CS, BDA08110CS, BDA08380DS
- BDV08230AY, BDV08024DY, BDV08024CY, BDV08110AY, BDV08012CY
- BDV08230A3, BDV08024D3, BDV08024C3, BDV08110A3, BDV08012C3, ATEX EX NA
- LBA05230AS, LBA05024AS, LBA05024CS, LBA05012CS, LBA05110AS
- BDA08036CS, BDA08042AS, BSA08223DS, BDP08223DS,
- LBV05024AV, LBV05024CY, LBV05110AY, LBV05230AY, LBV08024HU, LBV05024BW,
- LBA2X012CS, LBA2X024AS, LBA2X024CS, LBA2X110AS, LBA2X230AS,
- LBV05024A3, LBV05024B3, LBV0524C3, LBV05110A3, LBV05230A3,
- BDA1X004LS, BDA2X006LS, BDA05006LS, BDA05009LS, BDA1X0063S, BDA2X009LS,
- BDA05012LS, BDA1X009LS, BDA2X012LS, BDA10024LS, BDA1X012LS, BDA05024LS,
- BDA08115BS, BDA08200DS, BDA08240AS, BDV08110BW, UDV12230AY, UDV12230DW,
- UDA12024AS, UDA12024CS, UDA12110DS, UDA12230AS, UDV12024CY, UDV12112DW,
- GDH14024CS, GDH14024DS, GDH14110DS, GDH14223DS, GDV14024CY, GDV14024DY,
- GDV14110AY, GDV14230AY, GDV14024C3, GDV14024D3, GDV14110A3, GDV14230A3,
- GDH14018CS, GDH14077CS, GDA14012CS, ICA12024ES, ICA12024HS, ICA12230ES,
- compatible ode solenoid coils for watts solenoid valves
- PNEUMAX MB4, MB5, MB9, MB56, MB57, MB58, 22mm x 10mm
- CAMOZZI, U77, U7H, U7K, U7J,
- coil solenoid magnet electromagnet parker 12v 24v 110v 220v 240v
- PNEUMAX MF4, MF5, MF56, MF57, MF58, 12VDC, 24VDC, 24VAC, 110VAC, 220V,
- acl solenoid valve coil type 60114 24V dc 4w - idroenergiaitalia
- acl type 301 solenoid valve coil 24V dc 6.5w - idroenergiaitalia
- maintenance kit solenoid valve repair kit - ode - acl - idroenergiaitalia
-
Complete plunger, pistons, springs ode acl - idroenergiaitalia
- plunger-ode-21WA3K0B130-21WA4K0B130-21W3KB190-21W4KB250-21W5KB350-21W6KB400-21W7KB500
- R451234/T, 21LK1T40, 21L2K1T55, 21L1K1T40, 21A2KT45, 21A2KT55, 21A3KT45, 21A2KT55
- plunger piston ode 21L1K1T25 21L1K1T30 21L2K1T25 21L2K1T30 21X2KT120 21X3KT190 21X4KT250
- plunger-ode-21WA3K0V130-21WA4K0V130-21W3KV190-21W4KV250-21W5KV350-21W6KV400-21W7KV500
- R450675/v-31a3hlv11-PB- 31a3hv10-31a1av10-31a1av15-31a1av20-31a1av25-kt130hlv30-ac
- Water pump coffee machine Mokona Bialetti Saeco Gaggia Philips
- solenoid coils solenoid valves camozzi
- complete armature tube ode acl - idroenergiaitalia
-
membranes or complete diaphragm NBR FKM PTFE PBT for solenoid valves ode acl ceme parker
- R452186/B ode 21wa3r0b130, 21wa4r0b130, 21wa3k0b130, 21wa4k0b130,
- R452186/B-21wa3z0b130-21wa4z0b130-21wn3r0b130-21wn4r0b130-21WN3z0b130-21wn4z0b130
- R450431/B 21W3KB190-21W4KB250-21WN5KB190-21WN6KB250-21W3ZB190-21W4ZB250-21WN5ZB190-21WN6ZB250
- R450466/B-21W5KB350-21W6KB400-21W5ZB350-21W6ZB400-21WN7KB350-21WN8KB400-21WN7ZB350-21WN8ZB400
- R450432/B-21w7kb500-21w7zb500-21wn9kb500-21WN9ZB500
- R452186/V-21wa3r0v130-21wa4r0v130-21wa3k0v130-21wa4k0v130-21wn3k0v130-21wn4k0v130
- R452186/V-21wa3z0v130-21wa4z0v130-21wn3r0v130-21wn4r0v130-21WN3z0v130-21wn4z0v130
- R450431/V-21W3KV190-21W4KV250-21WN5KV190-21WN6KV250-21W3ZV190-21W4ZV250-21WN5ZV190-21WN6ZV250
- R450466/V-21W5KV350-21W6KV400-21W5ZV350-21W6ZV400-21WN7KV350-21WN8KV400-21WN7ZV350-21WN8ZV400
- R450432/V-21w7kv500-21w7zv500-21wn9kv500-21WN9Zv500,
- R452186/E-21wa3z0e130-21wa4z0e130-21wn3r0e130-21wn4r0e130-21WN3z0e130-21wn4z0e130
- R452186/E-21wa3r0e130-21wa4r0e130-21wa3k0e130-21wa4k0e130-21wn3k0e130-21wn4k0e130
- R450431/E-21W3KE190-21W4KE250-21WN5KE190-21WN6KE250-21W3ZE190-21W4ZE250-21WN5ZE190-21WN6ZE250
- R450466/E-21W5KE350-21W6KE400-21W5ZE350-21W6ZE400-21WN7KE350-21WN8KE400-21WN7ZE350-21WN8ZE400
- R450432/E-21w7ke500-21w7ze500-21wn9ke500-21WN9Ze500
- R451220/V DIAPHRAGM VITON FKM SOLENOID VALVE ODE 21H9KV180 21EN5KV180
- connectors IP65, IP67, atex, ul, csa, square, rectangular, for ode solenoid valves
- UL CSA certified pressure transducer or with EN175301-803 header connector
-
Coils solenoids magnets electromagnets ode acl camozzi parker pneumax ceme - idroenergiaitalia
Our webstore uses cookies to offer a better user experience and we recommend you to accept their use to fully enjoy your navigation.
Sign In
Accedi con account social
- Fai il login con Facebook
- Fai il login con Google
- Fai il login con PayPal
maddalena flanged irrigation counter DN80 - idroenergiaitalia
Installation guide Tangencial helix water meters WT Choice of the water meter Before installing the meter, ensure that the nominal diameter, flow rate, working temperature and pressure are compatible with the operating conditions. Transport and storage Water meters are precision instruments: handle with care and protect from shocks and vibration. Store the meters in a frost-free place; defrosting of the instruments is a delicate operation. Store the meters in a dry place, at a temperature between 0 °C and 50 °C. Do not expose to direct sunlight. Recommendations for the installation Before installing the meter, check that the two pipe sections are in-line in order to avoid mechanical stress, clean the two pipe sections carefully (especially if the piping is new) and allow water to flow in the pipe for some time using a pipe section instead of the meter. Install the meter where it will be safe from frost (if necessary protect the meter with insulating material) and possibly in the lowest part of the network in order to avoid air bubbles. Install the meter in a place where it will be protected from tampering and shocks, and easy to read. Install the meter ensuring that the flow direction arrow on the body points in the same direction as the flow. It is advisable to install a valve upstream and downstream of the meter, and flow straighteners in order to enable maintenance and verification of the meter and of the pipeline, and sealing. Installation position Always observe the inscriptions on the dial (letters H and V): o H: the meter must be installed in horizontal position o V: the meter must be installed in vertical position o H and V: the meter may be installed both in horizontal and vertical position o It is not advisable to install the meter in vertical position with descending flow or with the dial facing downwards Straight pipes and flow straighteners For the usage of upstream and/or downstream straight pipes refer to the letters U and D marked on the dial; if the letters U and/or D are followed by an S, a flow straightener must be installed. Admissible water pressure (ISO 4064-1) The maximum admissible pressure (MAP) is 16 bar and is indicated on the meter dial. If the maximum admissible pressure is not indicated on the dial, it shall be 10 bar. These values shall not be exceeded. The minimum admissible pressure (mAP) downstream of the meter outlet shall be greater than or equal to 30 kPa (0.3 bar). Start up Before starting up, release air from the pipeline and the meter (turning it, if necessary). Keep the shutoff valve completely open during this operation. Seals The meter is sealed: it cannot be opened without breaking the seal. Meters must be serviced only by an authorized centre. Pulser A pulser may be fitted on the meters (please refer to the instruction manual provided with the pulser). Declaration of conformity This is a shorter version of the declaration of conformity. The full version is available on the website www.maddalena.it. Maddalena S.p.A. hierby declares that the water meter model WT complies with the Directive 2004/22/EC and/or 2014/32/EU and the Standard EN 14154 and/or ISO 4064. EC/EU type-examination certificate (module B): TCM 142/13-5129.
-
Politiche per la sicurezza (modificale con il modulo Rassicurazioni cliente)
-
Politiche per le spedizioni (modificale con il Modulo rassicurazioni cliente)
-
Politiche per i resi merce (modificale con il Modulo rassicurazioni cliente)
Suitable for irrigation
Diameter: from 50 (Q3 40 m3 / h) mm to 200 mm (Q3 400 m3 / h)
Available in cold water version (T30)
R ≤ 40 H-V
Removable internal measuring part
Magnetic transmission
Installation in horizontal or vertical position
Prepared for reed switch pulse emitter
It can be connected to a radio module
Nominal pressure (PN): 10 bar or 16 bar
MID certificate
Certificate for use with drinking water (Ministerial Decree 174)